Open Log File = HMI_SC_ACE_LOG.TXT;  ;;;; 9-9-2004, 10:45:39 ;;;;;;
Shared Components Setup Source Version: R5.2.00.23
CompMasterFrame Name:   MasterFrame_Comp
CompMasterFrame Version:2002-10-09_R5.2.00.23_BaseIS553

    The SETUP is started from: E:\sw\simnetpc\wincc_ace\setup\

Files to delete: C:\WINDOWS\, HMI_SC_ACE_LOG.TXT.new
Commandline parameter: INTERPRETED: 
 
Official name of this Shared Component: SIMATIC WinCC ACE
Internal name: WinCC ACE
Release: V06.00.01.00_01.00.00.02
Version: 6.0
No MainProd found.

Setting setup language:
    Initial setup language dll: S7esetdb.DLL
     
    System language from DLL - ID: 3082
    System language: Spanish ID: 3082
    Get operating system (Win) language from KERNEL: Spanish ; D
    Get SetupLanguage as input-parameter of client from Registry: B
Display: Small Fonts
Display: Big window solution detected.

    Change Setup Language?
    The language DLL is up to date.
    After eventual change: Used language dll: S7esetdb.DLL

Allowable OS: WINNT40,WIN2000
    Operating System type: NT ; Real OS: Windows 2000 or higher
    Operating System ServicePack: 1
    Win 2000 allowed.
User has Administrator rights, O.K.

Main Path and Common Path determination:

Common directory
    Common Path exists: C:\Siemens\Common
    Base Dir is Common Path: C:\Siemens\Common
    Product not installed:   STEP7
    No MAIN directory existing: Do not copy to MAIN directory!!
     
    MS_SharedFiles_Counter:
       Body entry deleted: C:\Siemens\Common\s7acdlgx\s7acdlgx.dll
       Body entry deleted: C:\Siemens\Common\s7acdlgx\s7acdlgb.dll
       Body entry deleted: C:\Siemens\Common\s7acdlgx\s7acdlgd.dll
     

--- Test if Shared Component setup is new installation, overinstallation, update, install for new client:
Actual Component Release:               V06.00.01.00_01.00.00.02
Gotten Component Release from Registry: 
    
How to install component:
    New installation! No 'CLIENTS' key has existed; OK.


Deinstall Key: Comp_Def
Files to delete: C:\WINDOWS\Setup\WinCC ACE, DeIsL?.isu
Files to delete: C:\WINDOWS\Setup\WinCC ACE, Uninst.log

StartAppl
    Shall start CCAgent.EXE in C:\Siemens\Common\ACE\bin\
    ChangeDirectory to C:\Siemens\Common\ACE\bin for CCAgent.EXE in C:\Siemens\Common\ACE\bin\
    Could not find application CCAgent.EXE in C:\Siemens\Common\ACE\bin\
    Perhaps product is not installed!
    Shall start CCEClient.EXE in C:\Siemens\Common\ACE\bin\
    ChangeDirectory to C:\Siemens\Common\ACE\bin for CCEClient.EXE in C:\Siemens\Common\ACE\bin\
    Could not find application CCEClient.EXE in C:\Siemens\Common\ACE\bin\
    Perhaps product is not installed!
    Shall start CCEServer.EXE in C:\Siemens\Common\ACE\bin\
    ChangeDirectory to C:\Siemens\Common\ACE\bin for CCEServer.EXE in C:\Siemens\Common\ACE\bin\
    Could not find application CCEServer.EXE in C:\Siemens\Common\ACE\bin\
    Perhaps product is not installed!

Define the file set, printout all main parameters:
    ExtendedUninstallPath: C:\WINDOWS\Setup\WinCC ACE
    AUT Common Path:       C:\Siemens\Common
    MAIN Path:           C:\Siemens\Common

Transfer the files
Component install with SELFREGISTERBATCH

PerformFileTransfer:
    Target <WINDIR>    = C:\WINDOWS\
    Target <WINSYSDIR> = C:\WINDOWS\System32\
    Target <szTargDrv> = C:\WINDOWS\System32\Drivers
    Target <szTargCom> (Common Dir) = C:\Siemens\Common
    Target <TARGETDIR> (szBaseDir ) = C:\Siemens\Common

    Target <SvTargOwn> = C:\DOCUME~1\ww\CONFIG~1\Temp\_ISTMP3.DIR\_ISTMP0.DIR\
    Target <szTargExa> = C:\Siemens\Common\Examples
    Target <szTargPrv> = C:\WINDOWS\Setup\WinCC ACE
    Target <szTargMan> = C:\Siemens\Common
    Target <szTargIns> = C:\Siemens\Common\Install

    Successfully deselected WIN95 file groups (actual OS: NT)
    Successfully deselected WIN NT 4 file groups.

    Copy 'Data' containers!
Selected:
Common
   Common\LangIndep1
   Common\Lang1
   Common\Lang2
   Common\Lang3
   Common\Lang4
   Common\Lang5
   Common\CommonCore
ODBC30
   ODBC30\Core
   ODBC30\CoreDesk
   ODBC30\CodePage
   ODBC30\DBCommon
   ODBC30\UnInst
Program
   Program\LangIndep1
   Program\LangIndep2
   Program\Lang1
   Program\Lang2
   Program\Lang3
   Program\Lang4
   Program\Lang5
   Program\ProgramCore
Win
   Win\Win1
   Win\Win_2K
WinDrv
   WinDrv\WinDrv1
   WinDrv\WinDrv_2K
WinSys
   WinSys\WinSys1
   WinSys\WinSys_2K
Prg_S7_NT4_2K
Prg_Com_NT4_2K
S7Reg2K

    Size of 'Data' components: 8645003
    Successfully deselected WIN95 file groups (actual OS: NT)
    Successfully deselected WIN NT 4 file groups.

    Copy 'Data.cor' containers!
Core Components selected:
ODBC30
   ODBC30\Core
   ODBC30\CoreDesk
   ODBC30\CodePage
   ODBC30\DBCommon
   ODBC30\UnInst
Win
   Win\Win2
   Win\Win_2K_Core
WinDrv
   WinDrv\WinDrv2
   WinDrv\WinDrv_2K_Core
WinSys
   WinSys\WinSys2
   WinSys\WinSys_2K_Core

    Size of 'Data.cor' components: 852359

Check the copied files
 Input 'CheckFiles': IS_Output.txt
	 Number of files (incl. temp. and for all OS): 128, A,B,C,D,E
 Output			File
		Fl PC 	Fl InF 	D PC 		D InF		Version PC
 ------------------- Test done for IS_Output.txt
    All tested files: 128
    Really copied files: 128
    Filtered files (OS, lang., ..): 0
     
    System language from DLL - ID: 3082
    System language: Spanish ID: 3082
    Get operating system (Win) language from KERNEL: Spanish ; D
    - ExtendedUninstallPath: 

Get Wordpad Path
    Invalid Wordpad Path: "%ProgramFiles%\Windows NT\Accesorios\WORDPAD.EXE" "%1"
    Wordpad found: C:\ARCHIV~1\WINDOW~1\ACCESO~1\WORDPAD.EXE
    No Icon group (GroupName) specified. 
    Icons language: D
    Target Dir: C:\Siemens\Common
    FOLDER_STARTMENU : C:\Documents and Settings\All Users\Men Inicio\
    g_svStartMenuLoc : C:\Documents and Settings\All Users\Men Inicio\
    D_DEF_PROGGROUP  : Simatic
    szFolderPr       : 
    Program icons -  long path: C:\Documents and Settings\All Users\Men Inicio\
Per-Applications Path: , 
    Not longer in Registry: Software\Microsoft\Windows\CurrentVersion\App Paths\S7SharedComp
 
    Environment settings:
    Add NT Path: C:\Siemens\Common\Bin

START DeletePathInPATH.C:\Siemens\Common\Bin
    Part of PATH: C:\Siemens\SIMATIC_NCM\s7bin
    Remaining part of PATH: C:\Siemens\SIMATIC_NCM\s7bin
    Part of PATH: C:\Archivos de programa\Archivos comunes\ArchestrA\
    Remaining part of PATH: C:\Siemens\SIMATIC_NCM\s7bin;C:\Archivos de programa\Archivos comunes\ArchestrA\
    Part of PATH: %SystemRoot%\system32
    Remaining part of PATH: C:\Siemens\SIMATIC_NCM\s7bin;C:\Archivos de programa\Archivos comunes\ArchestrA\;%SystemRoot%\system32
    Part of PATH: %SystemRoot%
    Remaining part of PATH: C:\Siemens\SIMATIC_NCM\s7bin;C:\Archivos de programa\Archivos comunes\ArchestrA\;%SystemRoot%\system32;%SystemRoot%
    Part of PATH: %SystemRoot%\System32\Wbem
    Remaining part of PATH: C:\Siemens\SIMATIC_NCM\s7bin;C:\Archivos de programa\Archivos comunes\ArchestrA\;%SystemRoot%\system32;%SystemRoot%;%SystemRoot%\System32\Wbem
    Part of PATH: C:\Archivos de programa\Wonderware\InTouch\
    Remaining part of PATH: C:\Siemens\SIMATIC_NCM\s7bin;C:\Archivos de programa\Archivos comunes\ArchestrA\;%SystemRoot%\system32;%SystemRoot%;%SystemRoot%\System32\Wbem;C:\Archivos de programa\Wonderware\InTouch\
    END DeletePathInPATH. ErrorCode (Done >= 0): 0
    END RemovePartOfPath. ErrorCode (Done = 0): 0

START AddPath2Env.
    Replaced PATH in Registry with PATH = C:\Siemens\Common\Bin;C:\Siemens\SIMATIC_NCM\s7bin;C:\Archivos de programa\Archivos comunes\ArchestrA\;%SystemRoot%\system32;%SystemRoot%;%SystemRoot%\System32\Wbem;C:\Archivos de programa\Wonderware\InTouch\
    END AddPath2Env. ErrorCode (Done = 0): 0
    Environment needs reboot.
    Environment settings:
    Add NT Path: C:\Siemens\Common\ACE\Bin

START DeletePathInPATH.C:\Siemens\Common\ACE\Bin
    Part of PATH: C:\Siemens\Common\Bin
    Remaining part of PATH: C:\Siemens\Common\Bin
    Part of PATH: C:\Siemens\SIMATIC_NCM\s7bin
    Remaining part of PATH: C:\Siemens\Common\Bin;C:\Siemens\SIMATIC_NCM\s7bin
    Part of PATH: C:\Archivos de programa\Archivos comunes\ArchestrA\
    Remaining part of PATH: C:\Siemens\Common\Bin;C:\Siemens\SIMATIC_NCM\s7bin;C:\Archivos de programa\Archivos comunes\ArchestrA\
    Part of PATH: %SystemRoot%\system32
    Remaining part of PATH: C:\Siemens\Common\Bin;C:\Siemens\SIMATIC_NCM\s7bin;C:\Archivos de programa\Archivos comunes\ArchestrA\;%SystemRoot%\system32
    Part of PATH: %SystemRoot%
    Remaining part of PATH: C:\Siemens\Common\Bin;C:\Siemens\SIMATIC_NCM\s7bin;C:\Archivos de programa\Archivos comunes\ArchestrA\;%SystemRoot%\system32;%SystemRoot%
    Part of PATH: %SystemRoot%\System32\Wbem
    Remaining part of PATH: C:\Siemens\Common\Bin;C:\Siemens\SIMATIC_NCM\s7bin;C:\Archivos de programa\Archivos comunes\ArchestrA\;%SystemRoot%\system32;%SystemRoot%;%SystemRoot%\System32\Wbem
    Part of PATH: C:\Archivos de programa\Wonderware\InTouch\
    Remaining part of PATH: C:\Siemens\Common\Bin;C:\Siemens\SIMATIC_NCM\s7bin;C:\Archivos de programa\Archivos comunes\ArchestrA\;%SystemRoot%\system32;%SystemRoot%;%SystemRoot%\System32\Wbem;C:\Archivos de programa\Wonderware\InTouch\
    END DeletePathInPATH. ErrorCode (Done >= 0): 0
    END RemovePartOfPath. ErrorCode (Done = 0): 0

START AddPath2Env.
    Replaced PATH in Registry with PATH = C:\Siemens\Common\ACE\Bin;C:\Siemens\Common\Bin;C:\Siemens\SIMATIC_NCM\s7bin;C:\Archivos de programa\Archivos comunes\ArchestrA\;%SystemRoot%\system32;%SystemRoot%;%SystemRoot%\System32\Wbem;C:\Archivos de programa\Wonderware\InTouch\
    END AddPath2Env. ErrorCode (Done = 0): 0
    Environment needs reboot.

Selfregistration:

    Selfreg done.

Add REG - Files Registry:
 
ReplacePathVariables

Replacing PathVariables in .reg file: C:\Siemens\Common\S7Reg\ACE_PCS7_CCE.reg

Replacing PathVariables in .reg file: C:\Siemens\Common\S7Reg\DistribConfig.reg

Replacing PathVariables in .reg file: C:\Siemens\Common\S7Reg\RedundancyControl.reg

Replacing PathVariables in .reg file: C:\Siemens\Common\S7Reg\RPC.reg
 
Start searching for .reg Files!
Number of .reg files to register:5
    Add to Registry: C:\Siemens\Common\S7Reg\ACE_CCE.reg
    Add to Registry: C:\Siemens\Common\S7Reg\ACE_PC~1.REG
    Add to Registry: C:\Siemens\Common\S7Reg\DISTRI~1.REG
    Add to Registry: C:\Siemens\Common\S7Reg\REDUND~1.REG
    Add to Registry: C:\Siemens\Common\S7Reg\RPC.reg
REG-files deleted

Create the Component RegistryKey
    Uninstall: Software\Siemens\Shared Tools\WinCC ACE
    Product not installed:   STEP7

Selfregister Files by Regserver:
    ChangeWorkingDirectory to: C:\Siemens\Common\ACE\Bin
    Install "C:\Siemens\Common\ACE\Bin\RedundancyControl.exe" Result: 0
    DeinstallLogfileB1
    Install "C:\Siemens\Common\ACE\Bin\RedundancyState.exe" Result: 0
    DeinstallLogfileB1
    Waiting on Regsvr: 
    Install C:\WINDOWS\SETUP\Comp-Regsvr32.exe /S "C:\Siemens\Common\ACE\Bin\DistConf.dll" Result: 0
    DeinstallLogfileB1
    Waiting on Regsvr: 
    Install C:\WINDOWS\SETUP\Comp-Regsvr32.exe /S "C:\Siemens\Common\ACE\Bin\CCRedundancyNotifyServer.dll" Result: 0
    DeinstallLogfileB1
    ChangeWorkingDirectory to: C:\Siemens\Common\Bin
    Waiting on Regsvr: 
    Install C:\WINDOWS\SETUP\Comp-Regsvr32.exe /S "C:\Siemens\Common\ACE\Bin\CCAlgIAlarmDataMxServer.dll" Result: 0
    DeinstallLogfileB1
    Waiting on Regsvr: 
    Install C:\WINDOWS\SETUP\Comp-Regsvr32.exe /S "C:\Siemens\Common\ACE\Bin\CCAlarmParseMoniker.dll" Result: 0
    DeinstallLogfileB1
    ChangeWorkingDirectory to: C:\Siemens\Common\Bin
    Install "C:\Siemens\Common\ACE\Bin\CCAlgIAlarmDataProxyServer.exe" Result: 0
    DeinstallLogfileB1
    Waiting on Regsvr: 
    Install C:\WINDOWS\SETUP\Comp-Regsvr32.exe /S "C:\Siemens\Common\ACE\Bin\CCAlgIAlarmDataStubServer.dll" Result: 0
    DeinstallLogfileB1
    ChangeWorkingDirectory to: C:\Siemens\Common\Bin
    Waiting on Regsvr: 
    Install C:\WINDOWS\SETUP\Comp-Regsvr32.exe /S "C:\Siemens\Common\ACE\Bin\CCTlgIArchiveMxServer.dll" Result: 0
    DeinstallLogfileB1
    Waiting on Regsvr: 
    Install C:\WINDOWS\SETUP\Comp-Regsvr32.exe /S "C:\Siemens\Common\ACE\Bin\CCTlgParseMoniker.dll" Result: 0
    DeinstallLogfileB1
    ChangeWorkingDirectory to: C:\Siemens\Common\Bin
    Install "C:\Siemens\Common\ACE\Bin\CCTlgArchiveClient.exe" Result: 0
    DeinstallLogfileB1
    Waiting on Regsvr: 
    Install C:\WINDOWS\SETUP\Comp-Regsvr32.exe /S "C:\Siemens\Common\ACE\Bin\CCTxtITextMxServer.dll" Result: 0
    DeinstallLogfileB1
    Waiting on Regsvr: 
    Install C:\WINDOWS\SETUP\Comp-Regsvr32.exe /S "C:\Siemens\Common\ACE\Bin\CCTxtParseMoniker.dll" Result: 0
    DeinstallLogfileB1
    ChangeWorkingDirectory to: C:\Siemens\Common\Bin
    Install "C:\Siemens\Common\ACE\Bin\CCTxtProxy.exe" Result: 0
    DeinstallLogfileB1
    ChangeWorkingDirectory to: C:\Siemens\Common\Bin
    Waiting on Regsvr: 
    Install C:\WINDOWS\SETUP\Comp-Regsvr32.exe /S "C:\Siemens\Common\ACE\Bin\CCUaIUaBasicMx.dll" Result: 0
    DeinstallLogfileB1
    Waiting on Regsvr: 
    Install C:\WINDOWS\SETUP\Comp-Regsvr32.exe /S "C:\Siemens\Common\ACE\Bin\CCUaParseMoniker.dll" Result: 0
    DeinstallLogfileB1
    ChangeWorkingDirectory to: C:\Siemens\Common\Bin
    Install "C:\Siemens\Common\ACE\Bin\CCUAIUABasicProxyServer.exe" Result: 0
    DeinstallLogfileB1
    ChangeWorkingDirectory to: C:\Siemens\Common\ACE\Bin
    Waiting on Regsvr: 
    Install C:\WINDOWS\SETUP\Comp-Regsvr32.exe /S "C:\Siemens\Common\ACE\Bin\CCDmIVarMxServer.dll" Result: 0
    DeinstallLogfileB1
    Waiting on Regsvr: 
    Install C:\WINDOWS\SETUP\Comp-Regsvr32.exe /S "C:\Siemens\Common\ACE\Bin\CCDmParseMoniker.dll" Result: 0
    DeinstallLogfileB1
    ChangeWorkingDirectory to: C:\Siemens\Common\Bin
    Install "C:\Siemens\Common\ACE\Bin\CCDmIvarProxyServer.exe" Result: 0
    DeinstallLogfileB1
    Waiting on Regsvr: 
    Install C:\WINDOWS\SETUP\Comp-Regsvr32.exe /S "C:\Siemens\Common\ACE\Bin\CCDmIVarStubServer.dll" Result: 0
    DeinstallLogfileB1
    Waiting on Regsvr: 
    Install C:\WINDOWS\SETUP\Comp-Regsvr32.exe /S "C:\Siemens\Common\ACE\Bin\CCShellExtention.dll" Result: 0
    DeinstallLogfileB1
    ChangeWorkingDirectory to: C:\Siemens\Common\Bin
    Waiting on Regsvr: 
    Install C:\WINDOWS\SETUP\Comp-Regsvr32.exe /S "C:\Siemens\Common\ACE\Bin\CCGenericProxy.dll" Result: 0
    DeinstallLogfileB1
    ChangeWorkingDirectory to: C:\Siemens\Common\Bin
    Waiting on Regsvr: 
    Install C:\WINDOWS\SETUP\Comp-Regsvr32.exe /S "C:\Siemens\Common\ACE\Bin\CCGenericStub.dll" Result: 0
    DeinstallLogfileB1
    ChangeWorkingDirectory to: C:\Siemens\Common\Bin
    Waiting on Regsvr: 
    Install C:\WINDOWS\SETUP\Comp-Regsvr32.exe /S "C:\Siemens\Common\ACE\Bin\CCTlgStubServer.dll" Result: 0
    DeinstallLogfileB1
    ChangeWorkingDirectory to: C:\Siemens\Common\Bin
    Waiting on Regsvr: 
    Install C:\WINDOWS\SETUP\Comp-Regsvr32.exe /S "C:\Siemens\Common\ACE\Bin\CCTXTITextStubServer.dll" Result: 0
    DeinstallLogfileB1
    Waiting on Regsvr: 
    Install C:\WINDOWS\SETUP\Comp-Regsvr32.exe /S "C:\WINDOWS\System32\MelbReg.dll" Result: 0
    DeinstallLogfileB1
    ChangeWorkingDirectory to: C:\Siemens\Common\Bin
    Waiting on Regsvr: 
    Install C:\WINDOWS\SETUP\Comp-Regsvr32.exe /S "C:\Siemens\Common\ACE\Bin\CCDmLocalTagResolver.dll" Result: 0
    DeinstallLogfileB1
    ChangeWorkingDirectory to: C:\Siemens\Common\Bin
    Install "C:\Siemens\Common\ACE\Bin\SignServer.exe" Result: 0
    DeinstallLogfileB1
    ChangeWorkingDirectory to: C:\Siemens\Common\Bin
    Install "C:\Siemens\Common\ACE\Bin\CCEClient.exe" Result: 0
    DeinstallLogfileB1
    ChangeWorkingDirectory to: C:\Siemens\Common\Bin
    Install "C:\Siemens\Common\ACE\Bin\CCEServer.exe" Result: 0
    DeinstallLogfileB1
    ChangeWorkingDirectory to: C:\Siemens\Common\Bin
    Install "C:\Siemens\Common\ACE\Bin\CCAgent.exe" Result: 0
    DeinstallLogfileB1
    Waiting on Regsvr: 
    Install C:\WINDOWS\SETUP\Comp-Regsvr32.exe /S "C:\Siemens\Common\ACE\Bin\CCIVar2ProxyStub.dll" Result: 0
    DeinstallLogfileB1



StartApplAfter
    Shall start CCEClient.EXE in C:\Siemens\Common\ACE\bin\
    ChangeDirectory to C:\Siemens\Common\ACE\bin for CCEClient.EXE in C:\Siemens\Common\ACE\bin\
    Successfully started C:\Siemens\Common\ACE\bin\CCEClient.exe /Service, Returnvalue: 0
    Shall start CCEServer.EXE in C:\Siemens\Common\ACE\bin\
    ChangeDirectory to C:\Siemens\Common\ACE\bin for CCEServer.EXE in C:\Siemens\Common\ACE\bin\
    Successfully started C:\Siemens\Common\ACE\bin\CCEServer.exe /Service, Returnvalue: 0
    Shall start CCAgent.EXE in C:\Siemens\Common\ACE\bin\
    ChangeDirectory to C:\Siemens\Common\ACE\bin for CCAgent.EXE in C:\Siemens\Common\ACE\bin\
    Successfully started C:\Siemens\Common\ACE\bin\CCAgent.exe /Service, Returnvalue: 0



    Write Version:                  6.0
    Write Release:                  V06.00.01.00_01.00.00.02
    Write Corr:                     
    Display Name                    SIMATIC WinCC ACE
    Logfilename                     C:\WINDOWS\HMI_SC_ACE_LOG.TXT
    Uninstallkey exists before Move
    Move UNINSTALL                  C:\WINDOWS\IsUn040a.exe -a -y  -f"C:\WINDOWS\Setup\WinCC ACE\DeIsL1.isu" -c"C:\WINDOWS\System32\S7esetdx.dll
    Add Client:                     SIMATIC NET PC SOFTWARE
Result parameters in registry:
    Write ComponentEntry:           WinCC ACE
    Write Restart:                  1
    Write Logfilename:              C:\WINDOWS\HMI_SC_ACE_LOG.TXT
    Write SetupSucceeded:           1
    (Values '1' and '2': Setup successful.)
    Delete Client entry             

Log File Closed ;;;;; 9-9-2004, 10:47:21 ;;;;;;
             
--------------UninstInitialize Start-----------------

  UI:  ;01-03-2007;12:45:23
              
  UI:  WinCC ACE 6.0
  UI:  ---------------------
CheckDeinstComponents: WinCC ACE 6.0

  UI:  It is a Component
  UI:  - Clients found
  UI:  Number of Clients: 0

  UI:  Clients not found, Deinstall
  UI:  Citamisfile: C:\WINDOWS\citamis.str
  UI:  Eintrag in Citamisfile:         Deinst WinCC ACE;     Version: 6.0;01-03-2007;12:45:23

              
  UI:  START: SecPreCheckRunAppl-Section

              
  UI:  END: SecPreCheckRunAppl-Section

              
  UI:  START: SecPreStartAppl-Section

              
  UI:  END: SecPreStartAppl-Section

              
  UI:  START: SecPreDelPacks-Section

              
  UI:  START: SecPreDelComps-Section

              
  UI:  END: SecPreDelComps-Section

              
  UI:  START: SelfUnregister-Section

  UI:  File1: C:\Siemens\Common\ACE\Bin\RedundancyControl.exe
  UI:  WDir1: C:\Siemens\Common\ACE\Bin
  UI:  File2: C:\Siemens\Common\ACE\Bin\RedundancyState.exe
  UI:  WDir2: 
  UI:  File3: C:\Siemens\Common\ACE\Bin\DistConf.dll
  UI:  WDir3: 
  UI:  File4: C:\Siemens\Common\ACE\Bin\CCRedundancyNotifyServer.dll
  UI:  WDir4: 
  UI:  File5: C:\Siemens\Common\ACE\Bin\CCAlgIAlarmDataMxServer.dll
  UI:  WDir5: C:\Siemens\Common\Bin
  UI:  File6: C:\Siemens\Common\ACE\Bin\CCAlarmParseMoniker.dll
  UI:  WDir6: 
  UI:  File7: C:\Siemens\Common\ACE\Bin\CCAlgIAlarmDataProxyServer.exe
  UI:  WDir7: C:\Siemens\Common\Bin
  UI:  File8: C:\Siemens\Common\ACE\Bin\CCAlgIAlarmDataStubServer.dll
  UI:  WDir8: 
  UI:  File9: C:\Siemens\Common\ACE\Bin\CCTlgIArchiveMxServer.dll
  UI:  WDir9: C:\Siemens\Common\Bin
  UI:  File10: C:\Siemens\Common\ACE\Bin\CCTlgParseMoniker.dll
  UI:  WDir10: 
  UI:  File11: C:\Siemens\Common\ACE\Bin\CCTlgArchiveClient.exe
  UI:  WDir11: C:\Siemens\Common\Bin
  UI:  File12: C:\Siemens\Common\ACE\Bin\CCTxtITextMxServer.dll
  UI:  WDir12: 
  UI:  File13: C:\Siemens\Common\ACE\Bin\CCTxtParseMoniker.dll
  UI:  WDir13: 
  UI:  File14: C:\Siemens\Common\ACE\Bin\CCTxtProxy.exe
  UI:  WDir14: C:\Siemens\Common\Bin
  UI:  File15: C:\Siemens\Common\ACE\Bin\CCUaIUaBasicMx.dll
  UI:  WDir15: C:\Siemens\Common\Bin
  UI:  File16: C:\Siemens\Common\ACE\Bin\CCUaParseMoniker.dll
  UI:  WDir16: 
  UI:  File17: C:\Siemens\Common\ACE\Bin\CCUAIUABasicProxyServer.exe
  UI:  WDir17: C:\Siemens\Common\Bin
  UI:  File18: C:\Siemens\Common\ACE\Bin\CCDmIVarMxServer.dll
  UI:  WDir18: C:\Siemens\Common\ACE\Bin
  UI:  File19: C:\Siemens\Common\ACE\Bin\CCDmParseMoniker.dll
  UI:  WDir19: 
  UI:  File20: C:\Siemens\Common\ACE\Bin\CCDmIvarProxyServer.exe
  UI:  WDir20: C:\Siemens\Common\Bin
  UI:  File21: C:\Siemens\Common\ACE\Bin\CCDmIVarStubServer.dll
  UI:  WDir21: 
  UI:  File22: C:\Siemens\Common\ACE\Bin\CCShellExtention.dll
  UI:  WDir22: 
  UI:  File23: C:\Siemens\Common\ACE\Bin\CCGenericProxy.dll
  UI:  WDir23: C:\Siemens\Common\Bin
  UI:  File24: C:\Siemens\Common\ACE\Bin\CCGenericStub.dll
  UI:  WDir24: C:\Siemens\Common\Bin
  UI:  File25: C:\Siemens\Common\ACE\Bin\CCTlgStubServer.dll
  UI:  WDir25: C:\Siemens\Common\Bin
  UI:  File26: C:\Siemens\Common\ACE\Bin\CCTXTITextStubServer.dll
  UI:  WDir26: C:\Siemens\Common\Bin
  UI:  File27: C:\WINDOWS\System32\MelbReg.dll
  UI:  WDir27: 
  UI:  File28: C:\Siemens\Common\ACE\Bin\CCDmLocalTagResolver.dll
  UI:  WDir28: C:\Siemens\Common\Bin
  UI:  File29: C:\Siemens\Common\ACE\Bin\SignServer.exe
  UI:  WDir29: C:\Siemens\Common\Bin
  UI:  File30: C:\Siemens\Common\ACE\Bin\CCEClient.exe
  UI:  WDir30: C:\Siemens\Common\Bin
  UI:  File31: C:\Siemens\Common\ACE\Bin\CCEServer.exe
  UI:  WDir31: C:\Siemens\Common\Bin
  UI:  File32: C:\Siemens\Common\ACE\Bin\CCAgent.exe
  UI:  WDir32: C:\Siemens\Common\Bin
  UI:  File33: C:\Siemens\Common\ACE\Bin\CCIVar2ProxyStub.dll
  UI:  WDir33: 
              
  UI:  END: SelfUnregister-Section

              
  UI:  START: SecPreCallDll-Section

  UI: WARNING: Es wurden kein Aufruf von Dlls durchgefuehrt.
              
  UI:  END: SecPreCallDll-Section

              
  UI:  START: SecChangeAttrib-Section

              
  UI:  END: SecChangeAttrib-Section

  UI:  UninstInitialize() ok.
  UI:  ;01-03-2007;12:45:31
              
             
--------------UninstInitialize Ende------------------

             
--------------UninstUnInitialize Start---------------

  UI:  ;01-03-2007;12:45:34
              
  UI:  WinCC ACE 6.0
              
  UI:  START: DeleteRegKey-Section

              
  UI:  END: DeleteRegKey-Section

              
  UI:  START: SecPostDelComps-Section

              
  UI:  END: SecPostDelComps-Section

              
  UI:  START: SecPostEraseFiles-Section

              
  UI:  END: SecPostEraseFiles-Section

              
  UI:  START: SecPostDelDirs-Section

              
  UI:  END: SecPostDelDirs-Section

              
  UI:  START: SecPostEraseDirs-Section

              
  UI:  END: SecPostEraseDirs-Section

              
  UI:  START: SecPreStartAppl-Section

              
  UI:  END: SecPreStartAppl-Section

              
  UI:  START: CleanLanguageFolderInStartmenu

  UI:  END: CleanLanguageFolderInStartmenu

              
  UI:  Temporre Kommunikationsdatei C:\DOCUME~1\ww\CONFIG~1\Temp\d01f6.tmp geloescht.
  UI:  Kommunikationsdatei C:\WINDOWS\SETUP\WINCC ACE\uninst.log geloescht.
  UI:  Installationsverzeichnis C:\WINDOWS\SETUP\WINCC ACE\ geloescht.
  UI:  ;01-03-2007;12:45:34
              
  UI:  Citamisfile: C:\WINDOWS\citamis.str
  UI:  Eintrag in Citamisfile:         ----> done Deinst WinCC ACE

             
--------------UninstUnInitialize Ende----------------

